2021 Caterpillar Diesel Generator Sets 2001 + 3616 (50 Hz)

Information

2021 Caterpillar Diesel Generator Sets 2001 + 3616 (50 Hz)

Producing reliable power from 4700 to 7520 kVA at 50 Hz , our 3616 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 per cent rated load in one step. The generator set is certified for low fuel consumption.

Features may include:

CAT DIESEL ENGINE
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
GENERATOR
  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
WORLD WIDE PRODUCT SUPPORT
  • Cat dealers provide extensive post-sale support including maintenance and repair agreements.
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S? program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products
FULL RANGE OF ATTACHMENTS
  • Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation

Photos

Highlights

  • Red Deer, Alberta
  • 2021
  • Caterpillar
  • Diesel Generator Sets 2001 + 3616 (50 Hz)
  • Genset (maximum): 64470 kg (141840 lb)
  • Available
  • Maximum: 2530.3 mm (99.62 in)
  • Maximum: 3977.7 mm (156.6 in)

Specifications

  • 2021
  • Caterpillar
  • Diesel Generator Sets 2001 +
  • 3616 (50 Hz)
  • General
  • Model: 3616 V-16, 4-Stroke Water-Cooled Diesel
  • 720 & 1000 rpm
  • 280 mm (11 in)
  • 300 mm (11.8 in)
  • 296 l (18032 in³)
  • Emissions/Fuel Strategy: Low Fuel Consumption
  • TA
  • 13:01
  • Direct unit injection
  • Generator Set Monitoring System (GMS)
  • Minimum Rating: 4700 kVA | Maximum Rating: 7520 kVA | Voltage: 4160 to 13800 Volts | Frequency: 50 Hz
  • Maximum: 10261.7 mm (404 in)
  • Maximum: 2530.3 mm (99.62 in)
  • Maximum: 3977.7 mm (156.6 in)
  • Genset (maximum): 64470 kg (141840 lb)
  • Duty Cycle: Standby, Prime, Continuous